Sintered Metal Powder Metallurgy Parts For Auto Exhaust Valve

Products Range:
Â
MIM Processing | Molding, Injection, Debinding,Sintering ,Second Operation |
Applied Software | PRO/E, Auto CAD, Solid Works, UG, CAD/CAM/CAE |
Material | Iron-based Alloy,Stainless Steel,Tungsten Alloy,Carbide Alloy,Tool Steel , Fine Ceramic , Titanium Alloy |
Surface Finish | Electroplate,PVD,Sandblasting,Painting,Polishing,Laser Engraving etc. |
Tolerance Precision | +/-0.05~0.02mm, can also be customized. |
Dimension | As per customers' request |
Part Color | Â Silver, Red, Blue, Gold, Oliver, Black, White & etc. |
Samples | Â Acceptable |
Quality System | 100% inspection before shipment |
Lead Time | Based on the quantity of order (Usually 45Â days) |
Packing | Plastic tray, plastic bag and Carton, full consider of practical situation |
Shipping | Â By sea, By air, By DHL, UPS, TNT & etc. |
Certification | All products SGS,CTI and RoHs approved, All material REACH approved. |

The Main Material For MIM
MIM is applicable to wide range of materials which includes low alloy steel, stainless steel, tool steel, nickel-based alloys, tungsten alloy, carbide, titanium, magnetic materials, Kovar alloy and fine ceramics, etc.

Table 1 Typical MIM materials and applications:
Material System | Material Composition | Typical Applications |
Low Alloy Steel | Fe-2Ni , Fe-8Ni | Automobile,machinery and other industries,particularly in structural parts |
Stainless Steel | 316L,17-4PH,420,440C | Medical equipments, clocks,watches |
Carbide | WC-Co | Various tools,clocks,watches |
Ceramic | Al2O3 ,ZrO2 ,SiO2 | IT electronics, daily necessities,watches |
Heavy Alloys | W-Ni-Fe,W-Ni-Cu,W-Cu | The arms industry, communications,daily necessities |
Titanium | Ti,Ti-6Al-4V | Medical and military structural parts |
Magnetic Materials | Fe,NdFeB,SmCo5,Fe-Si | Magnetic properties of the various components |
Tool Steel | CrMo4,M2 | Tools |
Table 2 Typical properties of several MIM materials:
Materials | Density | Hardness | Tensile Strength | Elongation | |
g/cm³ | Rockwell | Mpa | % | ||
Fe-based alloys | MIM-2200(Sintered) | 7.65 | 45HRB | 290 | 40 |
MIM-2700(Sintered) | 7.65 | 69HRB | 440 | 26 | |
MIM-4605(Sintered) | 7.62 | 62HRB | 415 | 15 | |
MIM-4605(Quenching and tempering) | 7.62 | 48HRC | 1655 | 2 | |
Stainless steel | MIM-316L(Sintered) | 7.92 | 67HB | 520 | 50 |
MIM-17-4PH(Sintered) | 7.5 | 27HRC | 900 | 6 | |
MIM-17-4PH(Sintered) | 7.5 | 40HRC | 1185 | 6 | |
MIM-430L(Sintered) | 7.5 | 65HRB | 415 | 25 | |
Tungsten alloys | 95%W-Ni-Fe | 18.1 | 30 | 960 | 25 |
97%W-Ni-Fe | 18.5 | 33 | 940 | 15 | |
Carbide | YG8X | 14.9 | HRA90 | Bending Strength 2300 | Â |
Fine Ceramics | Al2O3 | 3.98 | HRA92 | Bending Strength 2300 | Â |

Manufacturing Equipment


FAQ
1.What is MIM technology ?
MIM (Metal Injection Molding) is a manufacturing technology that combines the shape making complexity of Plastic Injection Molding with the material flexibility of Powder Metallurgy.
2.How to get a quotation?
Please send us drawings in digs, dwg, step etc. together with detailed PDF.
If you have any requirements, please note, and we could provide professional advice for your reference.
Customer Inquiry →Engineering Communication →Cost Analysis →Sales Analysis →Quote to Customer
» 1-3 Work Days Only
» Submit RFQ with complete commercial terms
  Â
3. What if we do not have drawing?
Samples would be available, and we would send you drawing to confirm.Â
Of course, we would ensure the safety of the drawing.
  Â
4. How to pay?
For small quantity, we could provide Paypal, Paypal commission will be added to the order.
For the big one, T/T is preferred.
  Â
5. How to ship?
For small quantity, we have cooperation with TNT, FEDEX, UPS etc
For big quantity, air or sea would be available for you to choose.
Â
5.What about the packing details?
We attached our normal packing details.
If you have any special requirements, we would be willing to help.
Â
Introduction
Holter ECG Monitoring Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Analysis Software Function
1.The rate of checking RR wave up to 99.9%, which increased the accuracy of analysis without losing wave.
2.AI histogram function which can directly distinguish various abnormal ECG which can analyze faster.
3. Dynamic ECG [Channel Correct" function, which can correct mistakenly wearing that makes the analysis more accurate.
4.Lorenz and Demix analysis function, which can analyze more faster, more accurately. Single medical case can be completely analyzed in 10 min, which can reduce the physician`s work.
5.ST can be displayed in many kinds of form, which ensures that analyzing ST- Trends Diagram comprehensively, observing the whole or partial ST variety to analyze the specific area of myocardial ischemia.
6.Atrial fibrillation function can be recognized automatically and can distinguish atrial fibrillation case, give advice and generate analysis report .
7.Unique Cardiac Fatigue Index function, which can judge index of Cardiac Fatigue .High-risk groups can be found and early intervention treatment can be taken by the index, which can effectively judge the heart age and predict SCD (Sudden Cardiac Death).
8. P-wave analysis function, which can check cardiac arrhythmia (such as AVB).
9.According to the requirement of patients, options can be selected freely while printing report, which can save physician `s time
10. ECG can be printed by various forms according to the user`s requirement.
11.Pacemaker analysis function, which can analyze different pacemakers(such as AAI,VVI,DDD).
12.The comprehensive analysis system of stand-alone version with network version ,users can freely select any model.
13.Wire and wireless simultaneously transfer mode ,which reduce complicated performance.
14. Dynamic ECG and static ECG analysis system ,which reduced complex operations.
15. Time Domain and Frequency Domain function on HRV module can reflect the moderation effect of sympathetic and parasympathetic to the heart rate.
16.HRT function can predict myocardial infarction which has clinical value.
17.ST function which can check the exact time and length of myocardial ischemia in 24 hours.
Holter Monitor,Holter 24 Hours,Holter Recorder,Holter Ecg Monitoring System
Changchun Yingwang Times Digital Co., Ltd. , https://www.ccsdsm.com