Sewage flowmeter during the use of common faults and solutions

Sewage flowmeter during the use of common faults and solutions

Weihai Kunke flow meter professional sewage flow meter manufacturers

1. Sewage flowmeter failure phenomenon: fluid does not flow, flow display is not zero, or display value is unstable 2. Probable causes a. Transmission line shield is poorly grounded, external interference signal is mixed into the display instrument input b pipe vibration, impeller follows Jitter, resulting in false signal c. The closing valve is not closed due to leakage. Actually, the meter shows leakage quantity d. The internal circuit board of the meter or the deterioration of the electronic components is damaged. The resulting interference 3. The sewage flow meter solution a Check the shielding layer and display Whether the instrument terminals are well grounded b Reinforce the pipeline, or install brackets before and after the sensor to prevent vibration c Check or replace the valve d Take “short-circuit method” or check items one by one to determine the source of interference and identify the point of failure.

II. 1. Sewage flow meter failure Phenomenon: The flow rate is not reduced, but the flow rate is gradually decreased. 2. Probable causes a. Whether the sewage flow meter filter is clogged or not, if the filter pressure difference increases, it indicates that the debris has been blocked b. The spool on the flow sensor tube segment is loose, the valve opening is automatically reduced c The flowmeter sensor impeller is obstructed by debris or the bearing gap enters foreign matter, the resistance increases and the deceleration slows down 3. Solution: a Eliminates the filter b from the valve Check whether the handwheel adjusts the effective judgment. After confirmation, repair or replace c. Remove the sensor and clear it. If necessary, check again.

Three, 1. Sewage flow meter failure phenomenon: No flow when the fluid is flowing normally, the total number of counter words does not increase 2. Probable causes a Check the sewage flow meter power line, fuse, function selector switch and signal line with no open circuit or bad contact b Check the inside of the sewage flow meter display device printing plate, contacts and other contact failure c Inspect the sewage flow meter detection coil d Check the internal flow of sewage water meter sensor failure, the above-mentioned 1-3 checks are confirmed to be normal or have been troubleshooting, but there is still The fault phenomenon indicates that the fault is inside the sensor flow channel. It can check whether the impeller touches the inner wall of the sensor, whether there is any foreign matter stuck, and whether the shaft and the bearing are stuck or broken. 3. Sewage flow meter solution: a Use an ohmmeter to troubleshoot Fault point b Printed board failure inspection can replace the "backup version" method, replace the fault board and make a detailed inspection. c Make the position of the detection coil on the sensor body, turn the test head off, and use the iron sheet under the test head quickly. Move, if the number of counter words does not increase, check whether the coil breaks and the welding spot is removed to remove foreign matter, and clean or replace damaged. Member, after recovery or after blowing hand toggle wheel, should be no frictional sound, replacement of bearings and other parts should be re-check, the new meter factor is obtained.

Weihai Kunke flow meter professional sewage flow meter manufacturers

Suspended Platform

Suspended platform, as temporary suspended cradle platform, are widely applied in maintenance applications such as curtain fecade cleaning in high rise building, painting, glazing repairs, bill- board painting, cable installation and other outer working of high rise building up to 150 meters about 30 floors high. Our ZLP series suspended platform cradle, ZLP1000, ZLP800, ZLP630, ZLP500, ZLP400 and ZLP150, are good choices for fulfill above outside of wall work. Based on the different materials, the suspended platform could be divided into Aluminum Working Platform, steel Working Platform, galvanized Working Platform.

ZLP series temporarily installed suspended platform is an ideal access equipment for building facade construction, decoration, cleaning and maintenance. It can be also applied to other aerial working such as elevator installing, ship building, construction of dam, bridge, large chimney, etc.

This equipment is easy to operate, convenient to move and reliable in safety and much more efficient than traditional scaffolding.


Suspended Working Platform,Suspended Cradle Platform,Aluminum Working Platform,Suspended Construction Platform,Working Platform Cradle

SHEN YANG BAOQUAN BUSINESS CO., LTD , https://www.syconstructionhoist.com